Rear Panel Description
Connections
The AMB-OS AMR-100 Receiver has several connections to facilitate program playback
and transfers. The connectors are:
16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1. Power – A standard computer type power cable is used
2. RF – F-type Connector: L-Band input from the satellite antenna
3. RS-232 – 9-pin sub-d female (DTE) connector for serial communication (a modem cable
is needed to connect to a computer)
4. Ethernet – Standard RJ-45 Ethernet network cable connection
5. Reset Switch
Reboots the receiver without performing a power recycle.
Audio outputs:
There are two sets of digital outputs that correspond to the two stereo analog outputs.
They are listed in the same order as you see them on the back of the receiver from
left to right.
Digital – Port 1
6. AES-EBU – XLR type connector
7. SPDIF – BNC connector
8. Optical – standard optical cable
Digital – Port 2
9. AES-EBU – XLR type connector
10. SPDIF – BNC connector
11. Optical – standard optical cable
Analog – Port 1
12. XLR connector – Left channel
13. XLR connector – Right channel
Analog – Port 2
14. XLR connector – Left channel
15. XLR connector – Right channel
16. Relays – 25-pin sub-d connector (the connector pinout is described in the RELAY
SPECIFICATIONS section)